Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

(tick) Class 0 servo topology is recommended, but not required

 

...

ScanImage 5 DAQ Hardware

...

ScanImage 5 will use National Instruments PXI FlexRIO platform.

...

Tip

Stay tuned for a National Instruments ScanImage 5 configuration tool

We anticipate this may include small discounts on hardware

 

Required DAQ Components 

 

 

User-Selected DAQ Components 

 

Digitizer Module

...

Features in future versions (SI 2015 & beyond) may utilize the far
greater (~10x) image processing power of the PXIe-7975R, e.g. closed-loop experiments. 

Tip
titlePXIe-7961 loaners

The PXIe-7975R option will be supported by ScanImage 5 by August 2014.

Vidrio has a small pool of PXIe-7961R loaners

Loaners are intended for users who purchase a PXIe-7975R
but need to start using ScanImage 5 sooner than August

...

 

HTML Comment
<ul><li><h4 id="ScanImage5Info-ControlDAQHardware">Control DAQ Hardware</h4></li></ul><p>SI5 requires 1 to 3 additional <a href="http://www.ni.com/xseries/" class="external-link" rel="nofollow">X Series</a> multifunction data acquisition (DAQ) boards for resonant scanning operation.<br/> </p><div class="table-wrap"><table class="confluenceTable"><tbody><tr><th class="confluenceTh">Board #</th><th class="confluenceTh">Purpose</th><th class="confluenceTh">Req/Opt</th><th colspan="1" class="confluenceTh">Options</th></tr><tr><td class="confluenceTd">1</td><td class="confluenceTd">Y Galvo control</td><td class="confluenceTd">Required</td><td colspan="1" class="confluenceTd"><a href="http://sine.ni.com/nips/cds/view/p/lang/en/nid/207405" class="external-link" rel="nofollow">PXIe-6341</a></td></tr><tr><td colspan="1" class="confluenceTd">2</td><td colspan="1" class="confluenceTd">Pockels control</td><td colspan="1" class="confluenceTd">Optional</td><td colspan="1" class="confluenceTd"><a href="http://sine.ni.com/nips/cds/view/p/lang/en/nid/207405" class="external-link" rel="nofollow">PCIe-6321</a> or <a href="http://sine.ni.com/nips/cds/view/p/lang/en/nid/207405" class="external-link" rel="nofollow">PXIe-6341</a></td></tr><tr><td colspan="1" class="confluenceTd">3</td><td colspan="1" class="confluenceTd">Piezo/FastZ control</td><td colspan="1" class="confluenceTd">Optional</td><td colspan="1" class="confluenceTd"><a href="http://sine.ni.com/nips/cds/view/p/lang/en/nid/207405" class="external-link" rel="nofollow">PCIe-6321</a> or <a href="http://sine.ni.com/nips/cds/view/p/lang/en/nid/207405" class="external-link" rel="nofollow">PXIe-6341</a></td></tr></tbody></table></div><p><img class="emoticon emoticon-tick" src="/s/-42bkgb/9012/1t6dj0k/_/images/icons/emoticons/check.svg" data-emoticon-name="tick" alt="(tick)" data-emoji-short-name=":tick:" /><span> For boards 2 &amp;3, the PXIe option is moderately more expensive, but this 1) reduces wiring complexity between boards and 2) reduces the number of PCIe slots required in the computer (or makes more available) </span></p><p> </p><h2 id="ScanImage5Info-ScanImage2015GalvoScanningHardware">ScanImage 2015 Galvo Scanning Hardware </h2><p> </p><p>ScanImage 2015 will support various galvo scanning modes, including galvo-only and galvo-plus-resonant combinations. </p><p>This section lists hardware support for the SI5-Flex galvo scanning features to be provided by the SFN 2014 early-access release date.</p><h4 id="ScanImage5Info-DigitizerHardware">Digitizer Hardware</h4><p>ScanImage 2015 will support the following input digitizer options:</p><div class="table-wrap"><table class="confluenceTable"><tbody><tr><th class="confluenceTh">Family</th><th class="confluenceTh">Model Number(s)</th><th class="confluenceTh">Comments</th></tr><tr><td class="confluenceTd">PCIe X Series</td><td class="confluenceTd"><a href="http://sine.ni.com/nips/cds/view/p/lang/en/nid/207409" class="external-link" rel="nofollow">PCIe-6351</a>, <a href="http://sine.ni.com/nips/cds/view/p/lang/en/nid/207410" class="external-link" rel="nofollow">PCIe-6353</a></td><td class="confluenceTd">PCIe-6351/6353 recommended for no-Pockels/Pockels cases, respectively</td></tr><tr><td class="confluenceTd">PXIe X Series</td><td class="confluenceTd"><a href="http://sine.ni.com/nips/cds/view/p/lang/en/nid/209215" class="external-link" rel="nofollow">PXIe-6356</a>, <a href="http://sine.ni.com/nips/cds/view/p/lang/en/nid/209216" class="external-link" rel="nofollow">PXIe-6358</a></td><td class="confluenceTd">PXIe boards fit into <a href="http://sine.ni.com/nips/cds/view/p/lang/en/nid/207401" class="external-link" rel="nofollow">chassis</a> used for resonant scanning (if applicable). PXIe-6356/6358 recommended for no-Pockels/Pockels cases, respectively.</td></tr><tr><td colspan="1" class="confluenceTd">S Series</td><td colspan="1" class="confluenceTd"><a href="http://sine.ni.com/nips/cds/view/p/lang/en/nid/11888" class="external-link" rel="nofollow">PCI-6110</a></td><td colspan="1" class="confluenceTd">Not recommended for new systems, but will remain supported. A PCI slot and full-size computer case is required to house this board.</td></tr></tbody></table></div><table class="diff-macro"><thead><tr><th class="diff-macro-title">htmlcomment</th></tr></thead><tbody><tr><td class="diff-macro-properties"><table><tr><th>hidden</th><td>true</td></tr></table></td></tr></tbody><tbody><tr><td class="diff-macro-body"><pre>&lt;div class="table-wrap">&lt;table class="confluenceTable">&lt;tbody>&lt;tr>&lt;td colspan="1" class="confluenceTd">USB X Series&lt;/td>&lt;td colspan="1" class="confluenceTd">&lt;a href="http://sine.ni.com/nips/cds/view/p/lang/en/nid/209071" class="external-link" rel="nofollow">USB-6351&lt;/a>, &lt;a href="http://sine.ni.com/nips/cds/view/p/lang/en/nid/209072" class="external-link" rel="nofollow">USB-6353&lt;/a>,&lt;br/>&lt;a href="http://sine.ni.com/nips/cds/view/p/lang/en/nid/209077" class="external-link" rel="nofollow">USB-6356&lt;/a>&lt;/td>&lt;td colspan="1" class="confluenceTd">USB-6351/6353 recommended for no-Pockels/Pockels cases, respectively&lt;/td>&lt;/tr>&lt;/tbody>&lt;/table>&lt;/div></pre></td></tr></tbody></table><ul><li><h4 id="ScanImage5Info-ScannerHardware">Scanner Hardware</h4></li></ul><p>An X/Y analog-controlled galvo scanner pair is required.  Cambridge Technologies <a href="http://camtech.com/index.php?option=com_content&amp;view=article&amp;id=90&amp;Itemid=74" class="external-link" rel="nofollow">6210</a> or <a href="http://camtech.com/index.php?option=com_content&amp;view=article&amp;id=90&amp;Itemid=74" class="external-link" rel="nofollow">6215</a> galvo system (typ. with 3-6mm mirrors) is typical. Galvo system characteristics impact attainable line speed and performance of future scan modes.</p>
HTML Comment
hiddentrue
<div class="table-wrap"><table class="confluenceTable"><tbody><tr><td colspan="1" class="confluenceTd"><p>Some users elect to set up TPLSM microscopes from a microscope hardware manufacturer. The following information is provided as a benefit to users</p><p>Sutter: Full compatibility with ScanImage 5 resonant/galvo capabilities</p><p>Scientifica:</p>Thorlabs and Prai</td></tr></tbody></table></div>
 

Computer Hardware

Example tested ScanImage 5 computer systems will be provided by the early-access release date.

...