{composition-setup}
{cache:refresh=30d}
----
{comment}{toc:maxLevel=4}{comment}
{report-list:depth=1|injected=true}
{local-reporter:page:sorted children}
{report-header}* [About This Release|#AboutThisRelease]{report-header}{report-body}[%content:title%|#%content:title%]{report-body}
{report-list}
{comment}{hide-from:groups=ephus-users|users=@anonymous}{create-page:prompt=Enter section name|postfix=(%ident%)|addspace=true}Add new section!{create-page}{hide-from}{comment}
----
{report-block}
{local-reporter:page:sorted children}
{report-body:injected=trueheader}
{anchor:%content:title%AboutThisRelease}
h1. %content:title%
{center}[!Shared Pics^pencilEdit.jpg|width=16|height=16!|http://cnn.com]{center}
{panel:borderStyle=none}{include:%content:title%}{panelAbout This Release {hide-from:groups=ephus-users|users=@anonymous}{link-to:page edit|page=ScanImage r3.5.1 README}^\[Edit\]^{link-to}{hide-from}
{include:ScanImage r3.5.1 README}
{report-bodyheader}
{report-blockbody:injected=true}
{commentanchor:%content:title%}
h2h1. Appendix A: _Standard.ini_ Additions
This section summarizes *new* _state_ variables that have been added to ScanImage via the _standard.ini_ file, including both those that are meant to be user/rig-modified and those which should not generally be modified.
h5. Frequently Modified Variables
* _state.init.triggerInputTerminal: _
* _state.init.externalTriggerInputTerminal:_
* _state.init.externalTriggerTimeout_:
* _state.init.outputBoardClockTerminal:_
* _state.init.shutter.shutterBoardIndex:_ Specifies board index or name (DAQmx) for board on which the DIO line(s) employed for the shutter(s) are located
\\
\\
h5. Infrequently Modified Variables
* _state.init.minUnidirectionalLinePeriodGUI_: Specifies the smallest of the enumerated ms/line options to support for unidirectional scans. Values of ms/line s smaller (faster) than this are exclusively for bidirectional scanning.
* _state.init.maxBufferedGrabTime:_ Specifies the threshold of time for a Grab acquisition, above which data will be saved during the acquisition, instead of afterwards, where possible.
* _state.init.outputChanBufferTime:_ Specifies in time (seconds) the length of the data buffer for the output channels (mirrors and Pockels Cell(s)). Increasing this time increases the frame rate at which data logging and/or merge display can occur reliably, at some expense of memory. This will be computer dependent.
* _state.acq.inputVoltageRange:_Specifies input voltage range to use for PMT input boards. Typically 10V, but lower voltages can allow for more dynamic range. (_{*}NOTE:\_* This feature not currently supported\!)
* _state.acq.inputBitDepth_: Specifies ADC resolution of PMT input boards \-\- typically 12 bits
* _state.internal.fastParkFOVFactor_: Specifies the multipler of the full FOV amplitude to use when parking the beam quickly, e.g. when stopping-and-restarting focus during zoom or rotation update (Default=1.2)
*
h5. Non-modifiable Variables
Other variables added in ScanImage 3.5, which should not be modified by the user in their own _.INI_ files, are simply listed here.
* _state.internal.saveDuringAcquisition_
* _state.internal.framesPerFileGUI_
* _state.internal.framesPerFile_
* _state.internal.triggerTimer_
* _state.acq.saveDuringAcquisition_
* _state.acq.framesPerFile_
* _state.acq.externallyTriggered_
* _state.acq.infiniteFocus_
* _state.acq.bidirectionalScan_
* _state.acq.channelMerge_
* _state.acq.mergeFocusOnly_
* _state.init.hotKeysNeedCtl_
h5. Other _standard.ini_ changes
h2. Appendix B: Hardware Notes
\\
{comment%content:title% {hide-from:groups=ephus-users|users=@anonymous}{link-to:page edit|page=%content:title%}^\[Edit\]^{link-to}{hide-from}
{hide-from:groups=ephus-users|users=@anonymous}
{hide-from}
{include:%content:title%}
{report-body}
{report-block}
{cache} |