You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 46 Next »

 

Overview

ScanImage 5 will be released in two parts, SI5-Resonant and SI5-Flex.

 Early-Access
Release(s) 
ReleaseComments
SI5-ResonantMay 2014SFN 2014
  • Recapitulate ScanImage 4 (resonant scanning) features with
    more flexible and powerful NI FPGA hardware.
SI5-Flex

SFN 2014 &
March 2015

SFN 2015
  • By SFN 2014: Recapitulate ScanImage 3 (galvo scanning) features and add features requested by SI5 Founding Members
  • By March 2015: Support both galvo and resonant scanning modes plus multi-scanner modes for photostimulation,
    random-access imaging, and photoablation applications

Early-access releases will be available to ScanImage 5 founding members.

ScanImage 5 will have  customization layers for both CPU and FPGA-based processing (latter for resonant scanned imaging only) which can be used to implement online or real-time analysis, including closed-loop experiments with parallel imaging and (photo)stimulus.       

SI5-Resonant Scanning Hardware

For resonant scanned raster imaging, both digitizer hardware and scanner hardware are required.

Digitizer Hardware

ScanImage 5 Resonant will use National Instruments PXI FlexRIO platform.
The system consists of three components: PXI chassis, FPGA Module, and digitizer module.

For ScanImage 5, the following system configurations are supported & recommended:

 ChassisFPGA ModuleDigitizer AdapterComments
Basic
2 Channel
PXIe-1073PXIe-7961R
NI 5732Lowest cost, under $10K
Basic
4 Channel
PXIe-1073PXIe-7961R
NI 5734 

Performance
2 Channel 

PXIe-1073PXIe-7975RNI 5732PXIe-7975R supports greater real-time image processing possibilities. Support for NI 5732 model expected by August 2014.
Performance
4 Channel
PXIe-1073PXIe-7975RNI 5734PXIe-7975R supports greater real-time image processing possibilities. Support for NI 5732 model expected by August 2014.

August Releases

SI5 users are encouraged to wait until August 2014 to purchase a newystem. National Instruments typically releases new modules & devices around its annual NI Week event. Vidrio plans to support any new devices that provide added value for ScanImage applications

 

 

 

 

Scanner Hardware

Sutter Components

Sutter Instrument company offers a Resonant Scan Box component combining the required components in a sound-proof housing.

Both the Sutter standalone Resonant Scan Box and their full MOM-Resonant microscope system will be compatible with ScanImage 5.

New & Old CRS Scanner Models

ScanImage 5 supports the CRS Resonant Scanner system from Cambridge Technology. SI5 will support both 'classic' and newer versions of the CRS scanners.

The 'new' CRS scanner systems reportedly provide improved synchronization and are optimized for use at maximal scan angles. Vidrio engineers will test new scanner systems before April 1, 2014. Prospective ScanImage 5 users may elect to wait until this assessment before purchasing a scanner system.

For resonant scanned raster imaging, users require 1x each of:

Resonant Scanner: Cambridge Technologies CRS-8 or CRS-12 scanner (older or newer systems. Includes control board.

Galvo Scanner: Cambridge Technologies 6210 or 6215 galvo system (typ. with 4-6mm mirror), with servo control board. Other analog-control galvos also supported.

Notes

(warning) CRS-12 support will not be ready by the SI5-Resonant early-access release date; its support is planned by SFN 2014

(info) Galvo system's max slew rate can impact the frame rate achievable at larger fields-of-view. Slower slew rates require a larger number of resonant scanner line periods for galvo flyback.

SI5-Flex Galvo Scanning Hardware 

SI5-Flex will support various galvo scanning modes, including galvo-only and galvo-plus-resonant combinations. 

This section lists hardware support for the SI5-Flex galvo scanning features to be provided by the SFN 2014 early-access release date.

Digitizer Hardware

SI5-Flex will support the following input digitizer options:

FamilyModel Number(s)Comments
PCIe X SeriesPCIe-6351, PCIe-6353PCIe-6351/6353 recommended for no-Pockels/Pockels cases, respectively
PXIe X SeriesPXIe-6356, PXIe-6358PXIe boards fit into chassis used for resonant scanning (if applicable). PXIe-6356/6358 recommended for no-Pockels/Pockels cases, respectively.
S SeriesPCI-6110Not recommended for new systems, but will remain supported. A PCI slot and full-size computer case is required to house this board.

This page contains macros or features from a plugin which requires a valid license.

You will need to contact your administrator.

Scanner Hardware

An X/Y analog-controlled galvo scanner pair is required.  Cambridge Technologies 6210 or 6215 galvo system (typ. with 3-6mm mirrors) is typical. Galvo system characteristics impact attainable line speed and performance of future scan modes.

  

Computer Hardware

Example tested ScanImage 5 computer systems will be provided by the early-access release date.

 

 

 

 

 

 

 

 

 