Overview

ScanImage 5 will 1) unify resonant and galvo scanning capabilities and 2) support the use of generic resonant scanning hardware with FPGA processing. ScanImage 5 will support hardware configurations with combinations of resonant and galvo scanning (by SI 5.1).

ScanImage 5 will have  customization layers for both CPU and FPGA-based processing (latter for resonant scanned imaging only) which can be used to implement online or real-time analysis, including closed-loop experiments with parallel imaging and (photo)stimulus.       

Release Dates

 PrereleaseReleaseComments
ScanImage 5May 1, 2014Nov 1, 2014Recapitulate ScanImage 4 features with more flexible hardware
ScanImage 5.1Feb 1, 2015Nov 1, 2015New capabilities incorporating Founding Member requests

Resonant Scanning Hardware

For resonant scanned raster imaging, the following digitizer/scanner hardware is required:

Digitizer Hardware

ScanImage 5 Resonant will use National Instruments PXI FlexRIO platform. The system consists of a: PXI chassis, FPGA Module, and digitizer module.

PXI Chassis: PXIe-1073 chassis typical. More advanced chassis supported as well.

FPGA Module: PXIe-7961R (smaller FPGA) & PXIe-7966R (larger FPGA) supported

Digitizer Module: NI 5732 (2 Chans/80MHz) & NI 5734 (4 Chans/120MHz) supported

(tick) Users can refer to "Vidrio ScanImage 5" to configure a standard ScanImage 5 system with National Instruments representatives.

  • National Instruments can include extended warranty support for the hardware bundles, You will be given the option when placing the order. Please discuss with your local sales rep if you have questions.
  • ScanImage 5 will include pre-complied FPGA bitfiles - one for each of the four FPGA/Digitizer combinations above. Theis whitepaper shows how to download bitfiles to FPGA hardware.
  • The PXIe-7962R FPGA module will likely also be supported (bitfiles provided), but this will not be as extensively tested.
  • The 7961R is suited for core imaging capabilities and limited future extensibility. The 7966 supports greater future extensibility.
  • The standard PXIe-1073 chassis is a 5-slot 'remote controller' chassis connecting to the computer via a PCIe (PCI Express) card. Both PCIe card and cable are included.

Scanner Hardware

For resonant scanned raster imaging, users require 1x each of:

Resonant Scanner: Cambridge Technologies CRS-8 or CRS-12 scanner. Includes control board.

Galvo Scanner: Cambridge Technologies 6210 or 6215 galvo system (typ. with 4-6mm mirror). Other analog-control galvos also supported.

Notes

(warning) CRS-12 support may not be ready by ScanImage 5 prerelease. Its support is planned by ScanImage 5 release date.

(tick) Sutter can provide a scanner assembly with sound-proof housing, with accompanying electronics housing. If interested, please contact Rick Ayer at Sutter.

(info) Galvo system's max slew rate can impact the frame rate achievable at larger fields-of-view. Slower slew rates require a larger number of resonant scanner line periods for galvo flyback.

Galvo Scanning Hardware

For galvo scanned raster imaging and future scan modes:

Digitizer Hardware

ScanImage 5 Galvo will support the following input digitizer options:

FamilyModel Number(s)Comments
PCIe X SeriesPCIe-6351, PCIe-6353PCIe-6351/6353 recommended for no-Pockels/Pockels cases, respectively
PXIe X SeriesPXIe-6356, PXIe-6358PXIe boards fit into chassis used for resonant scanning (if applicable). PXIe-6356/6358 recommended for no-Pockels/Pockels cases, respectively.
S SeriesPCI-6110Not recommended for new systems, but will remain supported. A PCI slot and full-size computer case is required to house this board.

This page contains macros or features from a plugin which requires a valid license.

You will need to contact your administrator.

Scanner Hardware

An X/Y analog-controlled galvo scanner pair is required.  Cambridge Technologies 6210 or 6215 galvo system (typ. with 3-6mm mirrors) is typical. Galvo system characteristics impact attainable line speed and performance of future scan modes.

  

Computer Hardware

ScanImage 5 (resonant and galvo modules) is expected to run on standard multi-core machines (e.g. iCore7) with at least 4GB RAM and at least 4 PCIe slots.

Example tested ScanImage 5 computer systems will be provided at the prerelease date.

 

 

 

 

 

 

 

 